@@ -226,7 +226,7 @@ void PID_autotune(float temp, int extruder, int ncycles)
|
226
|
226
|
|
227
|
227
|
unsigned long ms = millis();
|
228
|
228
|
|
229
|
|
- if (temp_meas_ready == true) { // temp sample ready
|
|
229
|
+ if (temp_meas_ready) { // temp sample ready
|
230
|
230
|
updateTemperaturesFromRawValues();
|
231
|
231
|
|
232
|
232
|
input = (extruder<0)?current_temperature_bed:current_temperature[extruder];
|
|
@@ -1198,6 +1198,7 @@ static void set_current_temp_raw() {
|
1198
|
1198
|
redundant_temperature_raw = raw_temp_value[1];
|
1199
|
1199
|
#endif
|
1200
|
1200
|
current_temperature_bed_raw = raw_temp_bed_value;
|
|
1201
|
+ temp_meas_ready = true;
|
1201
|
1202
|
}
|
1202
|
1203
|
|
1203
|
1204
|
//
|
|
@@ -1507,16 +1508,14 @@ ISR(TIMER0_COMPB_vect) {
|
1507
|
1508
|
} // switch(temp_state)
|
1508
|
1509
|
|
1509
|
1510
|
if (temp_count >= OVERSAMPLENR) { // 10 * 16 * 1/(16000000/64/256) = 164ms.
|
1510
|
|
- if (!temp_meas_ready) { //Only update the raw values if they have been read. Else we could be updating them during reading.
|
1511
|
|
- set_current_temp_raw();
|
1512
|
|
- } //!temp_meas_ready
|
|
1511
|
+ // Update the raw values if they've been read. Else we could be updating them during reading.
|
|
1512
|
+ if (!temp_meas_ready) set_current_temp_raw();
|
1513
|
1513
|
|
1514
|
1514
|
// Filament Sensor - can be read any time since IIR filtering is used
|
1515
|
1515
|
#if HAS_FILAMENT_SENSOR
|
1516
|
1516
|
current_raw_filwidth = raw_filwidth_value >> 10; // Divide to get to 0-16384 range since we used 1/128 IIR filter approach
|
1517
|
1517
|
#endif
|
1518
|
1518
|
|
1519
|
|
- temp_meas_ready = true;
|
1520
|
1519
|
temp_count = 0;
|
1521
|
1520
|
for (int i = 0; i < TEMP_SENSOR_COUNT; i++) raw_temp_value[i] = 0;
|
1522
|
1521
|
raw_temp_bed_value = 0;
|