Include bed hysteresis setting in the example configs

gralco 9 年之前
父節點
當前提交
69c00aea4c

+ 2
- 1
Marlin/Configuration.h 查看文件

@@ -192,11 +192,12 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109/M190 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
200 201
 #define TEMP_BED_RESIDENCY_TIME 10  // (seconds)
201 202
 #define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
202 203
 #define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.

+ 6
- 1
Marlin/example_configurations/Felix/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 15  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/Felix/Configuration_DUAL.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 15  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/Hephestos/Configuration.h 查看文件

@@ -195,11 +195,16 @@
195 195
 //#define TEMP_SENSOR_1_AS_REDUNDANT
196 196
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
197 197
 
198
-// Actual temperature must be close to target for this long before M109 returns success
198
+// Extruder temperature must be close to target for this long before M109 returns success
199 199
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
200 200
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
201 201
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
202 202
 
203
+// Bed temperature must be close to target for this long before M190 returns success
204
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
205
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
206
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
207
+
203 208
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
204 209
 // to check that the wiring to the thermistor is not broken.
205 210
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/Hephestos_2/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/K8200/Configuration.h 查看文件

@@ -199,11 +199,16 @@
199 199
 //#define TEMP_SENSOR_1_AS_REDUNDANT
200 200
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
201 201
 
202
-// Actual temperature must be close to target for this long before M109 returns success
202
+// Extruder temperature must be close to target for this long before M109 returns success
203 203
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
204 204
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
205 205
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
206 206
 
207
+// Bed temperature must be close to target for this long before M190 returns success
208
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
209
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
210
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
211
+
207 212
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
208 213
 // to check that the wiring to the thermistor is not broken.
209 214
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/RigidBot/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 //#define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/SCARA/Configuration.h 查看文件

@@ -217,11 +217,16 @@
217 217
 //#define TEMP_SENSOR_1_AS_REDUNDANT
218 218
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
219 219
 
220
-// Actual temperature must be close to target for this long before M109 returns success
220
+// Extruder temperature must be close to target for this long before M109 returns success
221 221
 #define TEMP_RESIDENCY_TIME 3  // (seconds)
222 222
 #define TEMP_HYSTERESIS 2       // (degC) range of +/- temperatures considered "close" to the target one
223 223
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
224 224
 
225
+// Bed temperature must be close to target for this long before M190 returns success
226
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
227
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
228
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
229
+
225 230
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
226 231
 // to check that the wiring to the thermistor is not broken.
227 232
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/TAZ4/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/WITBOX/Configuration.h 查看文件

@@ -195,11 +195,16 @@
195 195
 //#define TEMP_SENSOR_1_AS_REDUNDANT
196 196
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
197 197
 
198
-// Actual temperature must be close to target for this long before M109 returns success
198
+// Extruder temperature must be close to target for this long before M109 returns success
199 199
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
200 200
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
201 201
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
202 202
 
203
+// Bed temperature must be close to target for this long before M190 returns success
204
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
205
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
206
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
207
+
203 208
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
204 209
 // to check that the wiring to the thermistor is not broken.
205 210
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/adafruit/ST7565/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/delta/biv2.5/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/delta/generic/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/delta/kossel_mini/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 5
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/delta/kossel_pro/Configuration.h 查看文件

@@ -198,11 +198,16 @@
198 198
 //#define TEMP_SENSOR_1_AS_REDUNDANT
199 199
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
200 200
 
201
-// Actual temperature must be close to target for this long before M109 returns success
201
+// Extruder temperature must be close to target for this long before M109 returns success
202 202
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
203 203
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
204 204
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
205 205
 
206
+// Bed temperature must be close to target for this long before M190 returns success
207
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
208
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
209
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
210
+
206 211
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
207 212
 // to check that the wiring to the thermistor is not broken.
208 213
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/delta/kossel_xl/Configuration.h 查看文件

@@ -215,11 +215,16 @@
215 215
 //#define TEMP_SENSOR_1_AS_REDUNDANT
216 216
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
217 217
 
218
-// Actual temperature must be close to target for this long before M109 returns success
218
+// Extruder temperature must be close to target for this long before M109 returns success
219 219
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
220 220
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
221 221
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
222 222
 
223
+// Bed temperature must be close to target for this long before M190 returns success
224
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
225
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
226
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
227
+
223 228
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
224 229
 // to check that the wiring to the thermistor is not broken.
225 230
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/makibox/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.

+ 6
- 1
Marlin/example_configurations/tvrrug/Round2/Configuration.h 查看文件

@@ -192,11 +192,16 @@
192 192
 //#define TEMP_SENSOR_1_AS_REDUNDANT
193 193
 #define MAX_REDUNDANT_TEMP_SENSOR_DIFF 10
194 194
 
195
-// Actual temperature must be close to target for this long before M109 returns success
195
+// Extruder temperature must be close to target for this long before M109 returns success
196 196
 #define TEMP_RESIDENCY_TIME 10  // (seconds)
197 197
 #define TEMP_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
198 198
 #define TEMP_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
199 199
 
200
+// Bed temperature must be close to target for this long before M190 returns success
201
+#define TEMP_BED_RESIDENCY_TIME 0   // (seconds)
202
+#define TEMP_BED_HYSTERESIS 3       // (degC) range of +/- temperatures considered "close" to the target one
203
+#define TEMP_BED_WINDOW     1       // (degC) Window around target to start the residency timer x degC early.
204
+
200 205
 // The minimal temperature defines the temperature below which the heater will not be enabled It is used
201 206
 // to check that the wiring to the thermistor is not broken.
202 207
 // Otherwise this would lead to the heater being powered on all the time.