Browse Source

Fixed Z-Probes NO/NC for Anycubic Kossel (#12083)

Kevin Velickovic 6 years ago
parent
commit
ea13a77dcb
1 changed files with 1 additions and 1 deletions
  1. 1
    1
      Marlin/src/config/examples/delta/Anycubic/Kossel/Configuration.h

+ 1
- 1
Marlin/src/config/examples/delta/Anycubic/Kossel/Configuration.h View File

@@ -700,7 +700,7 @@
700 700
 // Mechanical endstop with COM to ground and NC to Signal uses "false" here (most common setup).
701 701
 #define X_MIN_ENDSTOP_INVERTING false  // set to true to invert the logic of the endstop.
702 702
 #define Y_MIN_ENDSTOP_INVERTING false  // set to true to invert the logic of the endstop.
703
-#define Z_MIN_ENDSTOP_INVERTING (ANYCUBIC_PROBE_VERSION + 0 == 2) // V1 is NC, V2 is NO
703
+#define Z_MIN_ENDSTOP_INVERTING (ANYCUBIC_PROBE_VERSION + 0 == 1) // V1 is NO, V2 is NC
704 704
 #define X_MAX_ENDSTOP_INVERTING false  // set to true to invert the logic of the endstop.
705 705
 #define Y_MAX_ENDSTOP_INVERTING false  // set to true to invert the logic of the endstop.
706 706
 #define Z_MAX_ENDSTOP_INVERTING false  // set to true to invert the logic of the endstop.

Loading…
Cancel
Save