I use the movement options via LCD quite often. Especially to get the nozzle out of the way. I see no reason, why the 10mm option is disabled for the Z-Axis, this is why i always delete this line when i compile a new version.
If this is unwanted, please just close this PR
M100 had numerious changes and quit working. Part of the problem is
the overloading of the SERIAL_PROTOCOL functions. Also, some of the
address arithmatic was changed to use char *ptr and passing ptr into the
SERIAL_PROTOCOL functions caused them to try to print a string instead
of a number. M100 is working again. Let's keep it that way!
M100 has been expanded to now have a function int
free_memory_is_corrupted() that can be called from other code to see if
the free space is still contiguous. It may make sense to add a flag to
control its verbose nature but right now, the extra chit chat is very
helpful to know int free_memory_is_corrupted() is doing the right thing
and what it found at various points when it was called. A 'Show &
Tell' is coming up with int free_memory_is_corrupted().
Firmware was forgetting the z_fade_height in Planner, set by M420 Z<f>,
after each reset or loading settings from EEPROM. Added the float
z_fade_height to EEPROM-Storage, now remembers the value.